Dear Damian,
Thank you so much for your reply. It helped me a lot. However I have some questions about the project, hope you can help me:
1/ In your revised project, the Min BER parameter of the BER Analyzer is still = 1, Eye Height = 1. Is there any other way that I can use to calculate BER?
2/ In the Layout parameter, you set the symbol rate parameter is twice the bit rate (symbol rate = 5Gbps, bit rate = 2.5Gbps). However, I think the symbol rate is supposed to be lower than the bit rate.
3/ How can you calculate the delay compensation parameter in the Data Recovery?
Once again, thank you very much for you help.
Regards,
Jake.